1352 - Discrd Rcvd Lrg MSU Unsptd Outbnd SLK
An IP7 GPL receives a large MSU greater than 272 bytes, the BICC controlled feature is on, there are available routes for the destination point code, but selected outbound card does not support large MSUs.
Example
0049.1352 CARD 1113 INFO Discrd Rcvd Lrg MSU Unsprtd Outbnd SLK
LEN=50
SIO=04 OPC= 016-032-048 DPC= 032-032-048
DATA=01 02 03 04 05 06 07 08 09 0a 0b 0c
0d 0e 0f 10 11 12 13 14 15 16 17 18
19 1a 1b 1c
LSN=ls211
Report Date:12-12-15 Time:11:02:11
;
Note:
The length of the MSU (for example, LEN=50) includes the length of the SIF plus some other parameters. The length of these other parameters varies depending on the protocol managed by the LIM card issuing the UIM.Alarm Level: No alarm condition. The message is informational only.
Recovery
No action necessary.