This message indicates that any one of the MBR GTT Settypes (IMSI\MSISDN\VLRnb\SMRPOA\SMRPDA) is found twice in the FLOBR search path, and the fallback is set to "Yes" in the last matched translation. GTT is then performed on the basis of the last matched translation. This is a successful scenario.
    0028.1144    CARD 1103     INFO      GTT(FLOBR) warning: duplicate settype
                 SIO=03 OPC=4-123-5 DPC=6-018-7
                 CDPA:  NI=1  RI=0  GTI=04  SSNI=0  PCI=1
                        TT=25   NP=04  NAI=010  ADDR=123456789012345678901
                        PC=3-026-5           SSN=005
                 CGPA:  NI=1  RI=0  GTI=04  SSNI=0  PCI=1
                        TT=100  NP=07  NAI=012  ADDR=012345678901234567890
                        PC=-----------       SSN=004
                        LSN=ls2314n2 GTTSETIDX=211 215
Alarm Level: No alarm condition. The message is informational only.
Recovery
chg-gta command so that the same MBR GTT settype is not encountered in the search path again.