Go to primary content
Oracle® Communications EAGLE Unsolicited Alarm and Information Messages Reference
Release 46.7
E97338_01
Go To Table Of Contents
Contents

Previous
Previous
Next
Next

1034 - SCCP rcvd inv Cld Party - no SSN

The SCCP received a message from the network that it could not route and was discarded because no subsystem number was present in the called party address.

Example
RLGHNCXA21W 00-04-18 19:02:41 EST  EAGLE 31.3.0
0114.1034    CARD 1201,A  INFO   SCCP rcvd inv Cld Party - no SSN
SIO=03   OPC=001-001-001  DPC=002-002-002
CDPA LENGTH=000   MSG TYPE=04
CDPA: AI=10 PC=003-003-003  SSN=005  TT=250 
ADDR=12345678901234567890
LSN=A1234567
Legend
ADDR
Address
AI
Address Indicator
CDPA LENGTH
Called party address length
CGPA
Calling party address
DPC
Destination point code
LSN
Linkset name. The name must be unique.
MSG TYPE
Message type
OPC
Origination point code
PC
Point code for the SS7 end user (OPC).
SIO
Service information octet
SSN
Subsystem number
TT
Translation type

Alarm Level: No alarm condition. The message is informational only.

Recovery

The sender of the discarded message is using an invalid message format.

If there is only one occurrence, no action is necessary. However, if the condition continues, there may be a problem at the node that is sending the invalid message. Contact that node and inform them of the problem.