0479 - Link Not Monitored

This is a possible clearing condition for UAM 477, Congestion: Copy Function Deactivated or Sentinel Socket Inactive. This implies that the Link's attempt to establish monitoring session is not successful, hence, not being monitored. Therefore any monitoring alarms should be cleared.

Example
RLGHNCXA21W 00-12-07 12:01:43 EST  EAGLE 35.0.0 
0014.0479   SLK 1205,A nc00027  Link not Monitored
            SLC=03   FECLLI=testclli            CLASS=SAAL

Note:

The Class parameter in the example is optional.

Alarm Level: No alarm condition. The message is informational only.

Recovery

This message indicates a previous fault has been corrected.