Oracle® Communications EAGLE Unsolicited Alarm and Information Messages Reference Release 46.7 E97338_01 |
|
![]() Previous |
![]() Next |
This message indicates GTT failed when FLOBR encountered a duplicate GTT set name in the GTT search. This UIM is issued when the Fallback option is OFF in GTA entry. The MSU is discarded.
stpa1071501 09-04-24 10:01:40 EDT EAGLE5 41.0.0-62.23.1 7386.1413 CARD 2317 INFO GTT(FLOBR) failure: duplicate set name SIO=83 OPC= 14504-aa DPC= 07347-aa SCCP MSG TYPE=09 CDPA: NI=0 RI=0 GTI=04 SSNI=1 PCI=1 TT=036 NP=01 NAI=004 ADDR=106005000000000000000 PC= 07347-aa SSN=005 CGPA: NI=0 RI=0 GTI=04 SSNI=1 PCI=1 TT=085 NP=07 NAI=003 ADDR=206005000000000000000 PC= 14472-aa SSN=101 LSN=ls2314n2 GTTSETIDX=211 215 Report Date:09-04-24 Time:10:01:40
Alarm Level: No alarm condition. The message is informational only.
Recovery
Verify the provisioning of the GTT information using the
rtrv-gta
,
rtrv-gttsel
, and
rtrv-gttset
commands to determine why
the MSU encountered a duplicate GTT set name.