Oracle® Communications EAGLE Unsolicited Alarm and Information Messages Reference Release 46.7 E97338_01 |
|
![]() Previous |
![]() Next |
This message is generated because the MSU passed the SCCP conversion before the MAP screening and is of a different domain than the OPC of the inbound MSU. Therefore, the MSU is discarded and the Any Time Interrogation error (ATIER) is not generated.
RLGHNCXA21W 00-11-18 18:59:23 EST EAGLE 35.0.0 0018.1060 CARD 1103 INFO Map Screening cannot generate ATIER OPC=001-001-001 CDPA: NI=1 RI=0 GTI=04 SSNI=0 PCI=1 TT=250 NP=04 NAI=010 ADDR=123456789012345678901 PC=003-003-003 SSN=005 CGPA: NI=1 RI=0 GTI=04 SSNI=0 PCI=1 TT=100 NP=07 NAI=012 ADDR=012345678901234567890 PC=001-001-001 SSN=004 Op-Code=61 Forbidden Param=N/A Action=Discard
Alarm Level: No alarm condition. The message is informational only.
Recovery
The MSU indicated in the message was discarded.