1320 - FPT value Unprovisioned for Frame

This UIM is periodically raised at hourly intervals, starting at the system initialization time, for all the provisioned frames if the Frame Power Threshold value is not provisioned for that frame.

Example
RLGHNCXA21W 00-04-18 19:05:43 EST EAGLE 35.0
0021.1320 CARD 1113 INFO FTP value unprovisioned for frame CF00

Alarm Level: No alarm condition. The message is informational only.

Recovery

  1. Verify that the Frame Power Threshold value is not configured for the provisioned frame for which the UIM is generated by using the following command:

    rtrv-frm-pwr

  2. Configure the appropriate Frame Power Threshold value for the frame using the following command:

    ent-frm-pwr

    Otherwise, contact My Oracle Support (MOS) about the generated UIM.