This alarm indicates that one or more temporary keys used
to enable a controlled feature will expire within the next seven days.
Example
RLGHNCXA21W 00-02-07 11:02:30 EST EAGLE 5.0.0-32.0.0
** 0100.0367 SYSTEM Temp Key(s) expiring soon
Alarm
Level: Major
Recovery
Enter the following command to retrieve information
about controlled features:
rtrv-ctrl-feat:enable=temp
The output of the
rtrv-ctrl-feat:enable=temp command
displays information about the number of days left for temporarily enabled
features.
Following is an example of the output:
The following features have been temporarily enabled:
RLGHNCXA03W 99-01-07 00:57:31 EST EAGLE 5.0.0-32.0.0
Feature Name Partnum Status Quantity Trial Period Left
TPS 893000140 on 4000 6 days 5 hrs 3 mins
If you do nothing within the remaining trial period,
the critical alarm, “0368 - Temp Key(s) have expired” will display when the
trial period expires.
If you wish to acquire this feature permanently, you
can purchase it from Tekelec.
The alarm will be cleared when the purchased feature
is enabled using the
enable-ctrl-feat command.