The Requested Info parameter in incoming ATI NP query was invalid. Either, length of Requested Info parameter < 2, or the Requested Info parameter does not contain MNP Requested Info, or the parameter is badly formatted.
RLGHNCXA21W 07-07-21 12:01:43 EST EAGLE 39.2.0 0002.1402 SYSTEM INFO ATINPQ: Invalid Requested Info SIO=03 OPC=001-001-001 DPC=002-002-002 SCCP MSG TYPE=04 CDPA: NI=1 RI=0 GTI=04 SSNI=0 PCI=1 TT=250 NP=04 NAI=010 ADDR=1234567890901 PC=003-003-003 SSN=005 CGPA: NI=1 RI=0 GTI=04 SSNI=0 PCI=1 TT=100 NP=07 NAI=012 ADDR=012345677890 re cseCD123 GTTSET=3 203 46 Report Date:07-07-21 Time:16:20:19
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action necessary.