Go to primary content
Oracle® Communications EAGLE Unsolicited Alarm and Information Messages Reference
Release 46.7
E97338_01
Go To Table Of Contents
Contents

Previous
Previous
Next
Next

1228 - SCCP did not route - SS OOS

This message indicates that SCCP did not route a message because the destination subsystem (SSN) was Out-of -Service. The message was discarded.

Example
station1234 99-08-30 16:28:08 EST EAGLE 35.0.0
0019.1228 CARD 1104,A SCCP did not route - SS OOS
TRANSLATED PC=003-003-003 TRANSLATED SS=005
CDPA: NI=1 RI=0 GTI=04 SSNI=1 PCI=1
TT=250 NP=04 NAI=010 ADDR=123456789012345678901
PC=003-003-003 SSN=005
CGPA: NI=1 RI=0 GTI=04 SSNI=1 PCI=1
TT=100 NP=07 NAI=012 ADDR=012345678901234567890
PC=004-004-004 SSN=003
LSN=A1234567
Legend
ADDR
Address
CDPA
Called party address
CGPA
Calling party address
DPC
Destination point code
GTI
Global title indicator
MSG TYPE
Message type (for example, connection request, connection confirm, connection refused)
NAI
Nature of address indicator
NI
Network indicator value
NP
Numbering plan
OPC
Origination point code
PC
Point code
PCI
Protocol control information
RI
Routing indicator
SIO
Service information octet
SSN
Subsystem number
SSNI
Subsystem number indicator
TT
Translation type
TRANSLATED PC
Translated point code
TRANSLATED SS
Translated subsystem

Alarm Level: No alarm condition. The message is informational only.

Recovery

This indicates that an MSU was discarded because the DPCSSN to which it was addressed is out-of-service (OOS). Contact the distant end node to which this message refers and verify that action is being taken to bring the SCCP back into service.