Recovery Procedure for All Cards Without Flash Memory

Caution:

This procedure causes the identified card to reload, and should be used only during periods of low traffic or the maintenance window.
  1. Enter this command to verify the GPLs running for the card identified in the output:
    rept-stat-gpl:gpl=xxxxxxx
    where xxxxxxx is the GPL

    Note:

    Mismatched GPLs should occur only during upgrades or running a trial GPL.
    identified in the output.

    Example of the output:

    tekelecstp 03-07-03 16:53:23 EST  EAGLE5 32.0.0-55.0.0
        GPL Auditing  ON
        GPL        CARD      RUNNING            APPROVED      TRIAL
        SS7HC      1203      025-015-001 ALM   025-015-000   -----------
  2. Verify GPL Auditing is ON. If not, enter this command:
    chg-gpl:audit=on
  3. Enter the command to reload the card:
    init-card:loc=xxxx
    where xxxx is the card location stenciled on the shelf of the EAGLE 5 ISS

    Note:

    Wait for the card to finish loading before continuing.
  4. Enter the command to verify the approved GPLs match the running GPLs:
    rept-stat-gpl:gpl=xxxxxxx

    where xxxxxxx is the GPL identified in the output.

  5. If the GPLs match, you have completed this procedure.

    If the GPLs do not match, continue with the next step.

  6. Enter this command to determine which cards are in alarm condition (indicated by the acronym ALM in the rept-stat-gpl display):
    rept-stat-gpl
  7. Note which cards are in an alarm condition and contact My Oracle Support (MOS).