Go to primary content
Oracle® Communications EAGLE Commands Error Recovery Reference
Release 46.8
F11879 Revision 1
Go To Table Of Contents
Contents

Previous
Previous
Next
Next

E3435 Cmd Rej: To disable CRITALMINH, critical alarms cannot be inhibited

If critical alarms are inhibited in the system, then the critalminh=no parameter cannot be specified.

Recovery

  1. Display the inhibited critical alarms. Enter the rept-stat-trbl command.
    The letter I after the message reference number (MRN) indicates that the alarm has been inhibited. Critical alarms are identified by *C.
  2. Use the unhb-alm command to uninhibit the alarm. Refer to the command description in Commands User's Guide for assistance.
  3. Re-enter the chg-stpopts command that generated this error message.
    Contact My Oracle Support if this error message appears again. See My Oracle Support (MOS).