E4241 Cmd Rej: Link test must not be running on requested link

The act/dact-lbp and act-cdl commands cannot be entered while a signaling link test generated by the tst-slk command is running.

Recovery

  1. Display the status of the signaling links currently under test. Enter the rept-stat-tstslk command.
  2. Re-enter the command that generated this error message after the test is complete, re-enter the command for a different card and link, or stop the test. Refer to the command description in Commands User's Guide and to the Maintenance Guide for assistance.
    Contact My Oracle Support if this error message appears again. See My Oracle Support (MOS).