E4582 Cmd Rej: Single rte to APC or SAPC for IPGW LS allowed

For the ent/chg-rte commands, more than one route cannot be assigned to an APC or SAPC for an IPGWx linkset.

For the chg-ls command, an APC or SAPC cannot be assigned to an IPGWx linkset that is already assigned to a route involving another linkset.

For the ent-ls command, an APC cannot be assigned to an IPGWx linkset that is already assigned to a route involving another linkset.

Recovery

  1. Display the routes and associated linksets. Enter the rtrv-rte command.