E4978 Cmd Rej: BPIPADDR only valid for E5-SMxG being equipped but inhibited

For the chg-ip-card command, if the card in the location specified by the loc parameter is not an E5-SMxG-B or card is not inhibited then the bpipaddr and bpsubmask parameters cannot be specified.

Recovery

  1. Enter the rept-stat-card:loc=<card location> command to display the GPL type.
  2. Replace the cards if necessary. Refer to the Maintenance Guide for assistance.
  3. Inhibit the card if necessary. Refer to the command description in Commands User's Guide for assistance.
  4. Re-enter the chg-ip-card command that generated this error message, specifying a valid combination of parameters. Refer to the command description in Commands User's Guide for assistance.
    Contact My Oracle Support if this error message appears again. See My Oracle Support (MOS).