Go to primary content
Oracle® Communications EAGLE Commands Error Recovery Reference
Release 46.8
F11879 Revision 1
Go To Table Of Contents
Contents

Previous
Previous
Next
Next

E5037 Cmd Rej: MATCHSEQ cannot be set to NPTYPE, if TIF ASD Feature is ON

If the TIF ASD feature is turned on, then the matchseq=nptype parameter cannot be specified.

Recovery

  1. Display the status of the TIF ASD feature. Enter the rtrv-ctrl-feat command.
    If the feature does not appear in the output, then the feature is not enabled. If the feature has a status of OFF, then the feature is enabled but is not turned on.
  2. Turn off the feature if necessary. Refer to the TIF User's Guide for assistance.
  3. Re-enter the chg-tifopts command that generated this error message.
    Contact My Oracle Support for assistance. See My Oracle Support (MOS).