Go to primary content
Oracle® Communications EAGLE Commands Error Recovery Reference
Release 46.8
F11879 Revision 1
Go To Table Of Contents
Contents

Previous
Previous
Next
Next

E3407 Cmd Rej: LSL parameters not valid for card type

The parameter values specified for the signaling link are not supported for the links on the card specified by the loc parameter. Refer to the command description for the ent-slk command in the Commands User's Guide for valid parameters for each type of link.

Recovery

  1. Display the card configuration. Enter the rtrv-card command specifying the card location.
    The card type is shown in the TYPE field of the output.
  2. Re-enter the ent-slk command that generated this error message, specifying a valid combination of parameters for the card type. Refer to the command description in Commands User's Guide, the Database Administration - SS7 User's Guide (SS7 links) and to the Database Administration - IP7 User's Guide (IP links) for assistance.
    Contact My Oracle Support if this error message appears again. See My Oracle Support (MOS).