Go to primary content
Oracle® Communications EAGLE Commands Error Recovery Reference
Release 46.8
F11879 Revision 1
Go To Table Of Contents
Contents

Previous
Previous
Next
Next

E5299 Cmd Rej: PC and CGPC must be of same domain

The pc/pca/pci/pcn/pcn24 and cgpc/cgpca/cgpci/cgpcn/cgpcn24 parameters must have the same domain.

Recovery

  1. Display the point codes and associated domains. Enter the rtrv-dstn command.
    The domain of each point code is shown in the DMN field in the output.
  2. Revise the settings as necessary. Refer to the Database Administration - SS7 User's Guide or to the Database Administration - IP7 User's Guide for assistance.
  3. Re-enter the ent/chg/rtrv-gttact command that generated this error message, specifying a valid combination of parameters. Refer to the command description in Commands User's Guide and to the Database Administration - GTT User's Guide for assistance.