E4941 Cmd Rej: Rule with FPFX=* value cannot have AS with CA(x)=FPFX
If a rule contains a filter prefix with a wildcard value, then the rule cannot contain an Action Set where the FPFX Conditioning Action is specified.
Recovery
Display the existing rules. Enter the rtrv-npp-srs command.
Re-enter the ent/chg-npp-srs command that generated this error message, specifying a valid combination of parameters. Refer to the command description in Commands User's Guide and to the Numbering Plan Processor (NPP) User's Guide for assistance.