E2105 Cmd Rej: Invalid card TYPE and APPL load type combination

For the act-upgrade command, if a card with card type DCM is used, then values of ss7ipgw, ipgwi, iplim, and iplimi cannot be specified for the appl parameter.

Caution:

It is strongly recommended that this command be used only in conjunction with the system Upgrade Procedure for the target release. The Upgrade Procedure provides step-by-step information on performing an upgrade.

For the chg-card command, the value specified for the loc parameter must indicate a card with a card type of DCM that is running the IPLIM or IPLIMI application.

For the ent-card command, the values specified for the type and appl parameters must be compatible. Refer to the command description in Commands User's Guide for a list of compatible values.

Recovery

  1. Display the cards in the system. Enter the rtrv-card and rtrv-stp commands.
  2. Re-enter the command that generated this error message, specifying a valid combination of parameters. Refer to the command description in Commands User's Guide for assistance.
    Appendix A of the Commands User's Guide contains a list of valid Card and Application types for the ent-card command.
    Contact My Oracle Support if this error message appears again. See My Oracle Support (MOS).