Go to primary content
Oracle® Communications EAGLE Commands Error Recovery Reference
Release 46.8
F11879 Revision 1
Go To Table Of Contents
Contents

Previous
Previous
Next
Next

E3690 Cmd Rej: QH cannot be specified unless 15 min meas is turned ON

The 15 Minute Measurements feature must be turned on and the 15 Minute Measurements collection option must be on before the qh parameter can be specified.

Recovery

  1. Display the status of the 15 Minute Measurements feature. Enter the rtrv-ctrl-feat command.
    If the feature does not appear in the output, then the feature is not enabled. If the feature has a status of OFF, then the feature is enabled, but is not turned on.
  2. Turn on the 15 Minute Measurements feature if necessary. Refer to the Database Administration - System Management User's Guide for assistance.
  3. Display the status of the 15 Minute Measurements collection option. Enter the rtrv-measopts command.
  4. Turn on the 15 Minute Measurements collection option if necessary. Refer to the Measurements Reference for assistance.
  5. Re-enter the command that generated this error message, specifying a valid combination of parameters. Refer to the command description in Commands User's Guide for assistance.
    Contact My Oracle Support if the error message appears again. See My Oracle Support (MOS).