E5274 Cmd Rej: Link count exceeds max allowed for
scheduled UI reports
If the Integrated Measurements feature is turned on and
the link count exceeds 700 links, then the
systotstp=on, systottt=on, complnkset=on,
complink=on, gtwystp=on, and
gtwylnkset=on parameters cannot be
specified.
Recovery
Display the status of the Integrated Measurements
feature. Enter the
rtrv-ctrl-feat command.
If the feature does not appear in the output, then
the feature is not enabled. If the feature has a status of OFF, then the
feature is enabled, but is not turned on.
The Integrated Measurements feature cannot be turned
off after it has been turned on. Reduce the number of links as necessary. Refer
to
Database Administration - SS7 User's Guide
or
Database Administration - IP7 User's Guide
for assistance with deleting a link.
Re-enter the
chg-meas command that generated this
error message.