Go to primary content
Oracle® Communications EAGLE Commands Error Recovery Reference
Release 46.8
F11879 Revision 1
Go To Table Of Contents
Contents

Previous
Previous
Next
Next

E4620 Cmd Rej: E5-IPSM Card is not Present

For the chg-ctrl-feat command, all card locations that correspond to SEAS terminals must be provisioned with IPSM cards before the SEAS Over IP feature can be turned on.

For the chg-trm command, If the SEAS Over IP (SOIP) feature is turned on, then an IPSM card must be provisioned at the location corresponding to the specified SEAS terminal.

Recovery

  1. Display the cards configured in the system. Enter the rtrv-card command.
  2. Display the status of the SOIP feature. Enter the rtrv-ctrl-feat command.
    If the feature does not appear in the output, then the feature is not enabled. If the feature has a status of OFF, then the feature is enabled but is not turned on.
  3. As necessary, install and configure cards in the appropriate locations and enable and turn on the SOIP feature. Refer to the Database Administration - System Management User's Guide for assistance with both tasks.
  4. Re-enter the command that generated this error message.
    Contact My Oracle Support if this error message appears again. See My Oracle Support (MOS).