Go to primary content
Oracle® Communications EAGLE Commands Error Recovery Reference
Release 46.8
F11879 Revision 1
Go To Table Of Contents
Contents

Previous
Previous
Next
Next

E3265 Cmd Rej: Either MCPM or integrated meas is reqrd to turn on COLLECT

Either the Measurements Platform or the E5-OAM Integrated Measurements feature must be enabled before specifying collect=on.

Recovery

  1. Display the status of the Measurements Platform and Integrated Measurements features. Enter the rtrv-feat and rtrv-ctrl-feat commands, respectively.

    If the Meaurements Platform feature has a status of OFF in the rtrv-feat command output, then the feature is not turned on. If the Integrated Measurements feature does not appear in the rtrv-ctrl-feat output, then the feature is not enabled.

  2. Display the status of the Measurements Platform or Integrated Measurements collection function. Enter the rtrv-measopts command.
  3. Enable/turn on the desired feature and collection function as necessary. Refer to the Database Administration - System Management User's Guide for assistance.
  4. Re-enter the command that generated this error message.

Contact My Oracle Support if this error message appears again. See My Oracle Support (MOS).