The command was entered with a point code that contains different network types. Point codes are specified by the following parameters:
ANSI point code – ni, nc, ncm and for the enter and change commands — nni, nnc, nncm
ITU-I point code – zone, area, id and for the enter and change commands — nzone, narea, nid
ITU-N point code – npc and for the enter and change commands — nnpc
ITU-N24 point code - msa, ssa, sp and for the enter and change commands — nmsa, nssa, nsp
An example of a point code containing different network types (i.e., mixed types of point codes) is ni-area-npc
. This is not allowed. If any of the enter and change commands are entered, an existing point code of one network type can be changed to another network type—as long as all the proper parameters are used.
Recovery
Re-enter the command that generated this error message, specifying a valid combination of parameters. Refer to the command description in the Commands User's Guide to the Database Administration - GWS User's Guide (Gateway Screening commands) and to the Database Administration - IP7 User's Guide (Route key commands) for assistance.