Go to primary content
Oracle® Communications EAGLE Commands Error Recovery Reference
Release 46.8
F11879 Revision 1
Go To Table Of Contents
Contents

Previous
Previous
Next
Next

E2501 Cmd Rej: Mixed point code types are not allowed

The command was entered with a point code that contains different network types. Point codes are specified by the following parameters:

ANSI point code – ni, nc, ncm and for the enter and change commands — nni, nnc, nncm

ITU-I point code – zone, area, id and for the enter and change commands — nzone, narea, nid

ITU-N point code – npc and for the enter and change commands — nnpc

ITU-N24 point code - msa, ssa, sp and for the enter and change commands — nmsa, nssa, nsp

An example of a point code containing different network types (i.e., mixed types of point codes) is ni-area-npc. This is not allowed. If any of the enter and change commands are entered, an existing point code of one network type can be changed to another network type—as long as all the proper parameters are used.

Recovery

Re-enter the command that generated this error message, specifying a valid combination of parameters. Refer to the command description in the Commands User's Guide to the Database Administration - GWS User's Guide (Gateway Screening commands) and to the Database Administration - IP7 User's Guide (Route key commands) for assistance.