Go to primary content
Oracle® Communications EAGLE Commands Error Recovery Reference
Release 46.8
F11879 Revision 1
Go To Table Of Contents
Contents

Previous
Previous
Next
Next

E3837 Cmd Rej: Command not valid for IPGHC

The act-lpo command is not valid for cards running the IPGHC GPL.

The blk-slk command is not valid for cards running IPGHC links.

For the ent-rte command, all routes with ANSI DPCs must use ANSI linkset APCs. A route with an ITU-I DPC can go over an ITU-N APC and an ITU-N DPC can go over an ITU-I APC.

The rept-stat-tstslk command cannot be entered for E5-ENET or E5-ENET-B cards that are running the IPGHC or IPSG application, or that have IPGHC or IPSG-M3UA links.

The tst-slk command is not valid for cards running the IPGHC application.

The ublk-slk command is not valid for E5-ENET or E5-ENET-B cards with IPGHC links.

Recovery

  1. Display the information for the card. Enter the rtrv-card command.
    Information on the card type and application is shown in the TYPE and APPL fields of the output.
  2. If necessary, display the signalling link and linkset information for the card. Enter the rtrv-slk and rtrv-ls commands, respectively.
  3. Replace the cards if desired. Refer to Maintenance Guide for assistance.
  4. Re-enter the command that generated this error message, specifying a valid combination of parameters. Refer to the command description in Commands User's Guide for assistance.
    Contact My Oracle Support if this error message appears again. See My Oracle Support (MOS).