E4127 Cmd Rej: Only one ITU-I or 24-bit ITU-N APC/SAPC allowed per linkset

Only one secondary adjacent point code or adjacent point code is allowed per linkset in an ITU-I or 24-bit ITU-N domain.

Recovery

  1. Display the linkset information. Enter the rtrv-ls:lsn command.
  2. Revise the settings as desired. Refer to the Database Administration - SS7 User's Guide for assistance.
  3. Re-enter the chg-ls command that generated this error message.
    Contact My Oracle Support if this error message appears again. See My Oracle Support (MOS).