E2181 Cmd Rej: ANSI PC is identical to ANSI CPC

The specified ANSI point code (pca) cannot match the ANSI capability point code (cpca).

Recovery

  1. Verify the ANSI capability point code in the system. Enter the rtrv-sid command.
    The ANSI capability point code is shown in the CPCA field of the output.
  2. Display the destination point codes in the database. Enter the rtrv-dstn command.
    The ANSI destination point codes are shown in the DPCA field of the output.
  3. Display the adjacent point codes in the database. Enter the rtrv-ls command.
    The ANSI adjacent point codes are shown in the APCA field of the output.
  4. Re-enter the chg-sid command that generated this error message, specifying a valid combination of parameters. Refer to the command description in Commands User's Guide and to the Database Administration - SS7 User's Guide for assistance.
    Contact My Oracle Support if this error message appears again. See My Oracle Support (MOS).