0088 - Clocks A and B TSCs are Out of Sync

It was detected by the OAM that clocks A and B have been out of synch for a excessive period of time. This alarm indicates the clock sources being used for TSCSYNC feature have failed or a hardware failure in the OAM card. This may impact the EAGLE Integrated Monitoring Support feature functionality.

Example
RLGHNCXA21W 00-02-07 12:01:43 EST  EAGLE 35.0.0
** 0014.0088 ** CARD 1113 EOAM   Clocks A and B are out of sync

Alarm Level: Major

Recovery

  1. Check the status of the OAM card by entering the following command:
    rept-stat-card:loc=xxxx

    where xxxx is the card location in the output.

  2. Verify the status of the system clocks with the rept-stat-clock command. If Eagle is reporting the clock alarm indicating a problem with clock sources, then check the status of the clock sources, the cables, and termination points. Refer to Clock System Alarms for additional details on handling clock-specific UAMs.
  3. Reseat the OAM card.
  4. If the problem persists, replace the OAM card.