0161 - 1116-P Clock Failed

This message indicates that the primary clock on the TDM card in slot 1116 failed.

Example
RLGHNCXA21W 00-12-07 12:01:43 EST  EAGLE 35.0.0 
*  0014.0161  * CLOCK SYSTEM    1116-P clock failed

Alarm Level: Minor

Recovery

  1. Use the rept-stat-clk command to determine the current clock configuration.
    Example of the output:
    tekelecstp 00-04-23  13:34:15 EST  EAGLE 35.0.0
        CARD LOC= 1114 (Standby  )    CARD LOC= 1116 (Active )
        PRIMARY BITS   = Idle       PRIMARY BITS   = Fault
        SECONDARY BITS = Active     SECONDARY BITS = Active
                                      PST           SST       AST
        SYSTEM CLOCK                  IS-NR         Idle      ------ 
        # Cards using CLK A = 0     # Cards with bad CLK A = 0
        # Cards using CLK B = 8     # Cards with bad CLK B = 0
        # Cards using CLK I = 0
        Command Completed.
  2. The system automatically reverts from the primary to secondary BITS if the primary clock fails.
    Reseat the TDM card in slot 1116.
  3. If the problem persists, replace the TDM card in slot 1116.
    Refer to the Maintenance Manual for card removal/replacement procedures.