0276 - Insufficient HW for IP7 Provisioning

The DCM or EDCM does not have enough memory to provision for sockets and associations.

Example
RLGHNCXA21W 00-02-07 11:02:30 EST  EAGLE 35.0.0
** 0100.0276 ** CARD  1115 DCM   Insufficient HW for IP7 provisioning
                HW VERIFICATION CODE: xxx

Alarm Level: Major

Recovery

  1. If this message contains the optional line ‘HW VERIFICATIONCODE: xxx’:
    1. Decode the xxx value and correct the indicated problem.
      See Hardware Verification Codes in UAMs the section on hardware verification codes in the Unsolicited Alarms and Information Messages manual.
    2. After correcting the problem, the card will be in out-of-service maintenance disabled state (OOS-MT-DSBLD).
      Restore the card back to in-service normal state (IS-NR) with the alw-card command.
    If this message does not contain the optional line ‘HW VERIFICATIONCODE: xxx’, continue with the next step.
  2. Verify the DCM/EDCM hardware.
    Verify the provisioning rules.

    Table 3-3 Maximum Sockets/Associations per Card

    Card Type Socket to Association Ratio Maximum Associations Maximum Sockets
    DCM 8:1 50 4
    EDCM 1:1 50 50
  3. If necessary, reduce the number of associations to four or less for DCMs or 50 or less for EDCMs.
    Refer to the Database Administration Manual - IP7 Secure Gateway for detailed provisioning information.