0368 - Temp Key(s) have expired

This alarm indicates that one or more temporary keys used to enable a controlled feature have expired.

Example
   RLGHNCXA21W 00-02-07 11:02:30 EST  EAGLE 5.0.0-32.0.0
*C 0100.0368    SYSTEM     Temp Key(s) have expired

Alarm Level: Critical

Recovery

  1. Enter the following command to retrieve information about controlled features: rtrv-ctrl-feat:expired=yes
    The output of the rtrv-ctrl-feat:expired=yes command displays information about expired temporarily enabled features.
    Following is an example of the output:
    
    RLGHNCXA03W 99-01-07 00:57:31 EST EAGLE 5.0.0-32.0.0
    The following features have expired temporary keys:
    Feature Name              Part Num
    TPS 8930000140
    
  2. You can enter the chg-ctrl-feat:partnum=893xxxxxx:alarm=clear command to clear this alarm.
  3. If you wish to acquire this feature permanently, you can purchase it from Tekelec and enable it using the enable-ctrl-feat command.
    The alarm will clear when the purchased feature is installed with a permanent key.