0516 - Degraded Mode - 1 Card Failed

Measurements are degraded because a card is out of service:

  • If the E5-OAM Integrated Measurements feature is in use, the problem is that one E5-MCAP card is out of service.

  • If the Measurements Platform is in use, the problem is that one MCPM card is out of service.

The E5-OAM Integrated Measurements feature or the Measurements Platform (depending on which is in use) can successfully complete all of its work, but with no spare E5-MCAP card or no spare MCPM card.

Example
RLGHNCXA21W 00-02-07 11:02:30 EST  EAGLE 35.0.0
*  0100.0516 * MEAS SYSTEM    Degraded Mode - 1 card failed

Alarm Level: Minor

Recovery

  1. Enter the following command to determine the status of the E5-MCAP or MCPM card:.
    rept-stat-meas
  2. Reinitialize the faulty card using the init-card command.
  3. If the fault has not cleared, reseat the faulty card.
  4. If the fault has not cleared, replace the faulty card:
    • If you use E5-OAM Integrated Measurements, the E5-MCAP card is out of service. The E5-MCAP card is part of the E5-MASP card assembly, so replace the E5-MASP card.
    • If you use the Measurements platform, replace the MCPM card.
    Refer to the Maintenance Manual for card removal/replacement procedures.