0573 - BERT Test Failed

This message is displayed when the BERT diagnostic test, which is initiated by the HIPR2 card as a part of the IMT bus alignment process, has failed. This message may indicate that a HIPR2 card has failed; it may also indicate that there is a bad high rate Fibre-Channel cable, or that the high rate Fibre-Channel cables have not been installed.

Example
RLGHNCXA21W 09-02-07 12:01:43 EST  EAGLE 41.1.0
**  0590.0573 ** Card 1109         BERT Test Failed

Alarm Level: Major

Recovery

  1. Determine the status of the HIPR2 cards using the command: rept-stat-mux.
    Replace any faulty HIPR2 card with a new HIPR2 card.
  2. Verify that the high rate Fibre-Channel cables have been installed.
  3. Inspect the cables and verify that the cable connections are secure.
  4. The BERT test will run again during the bus alignment. Once the BERT Test is successful, the alarm will be cleared.
  5. Contact My Oracle Support (MOS) for more information.