1002 - MTP rcvd invalid TFC - status 0
The EAGLE 5 ISS system received a transfer controlled (TFC) message with a status of 0 (protocol violation). No action on the part of the EAGLE 5 ISS system has been taken.
 
                     		  Example 
                     		  
 
                  		
                  RLGHNCXA21W 00-02-07 11:02:30 EST  EAGLE 35.0.0
   0100.1002    CARD 1205,B  INFO   MTP rcvd invalid TFC - status 0
SIO=0a   OPC=003-234-000  DPC=000-024-000
AFTPC=055-000-046  CONG STATUS=000
LSN=A1234567 
                     		  Legend 
		   
                     		
                      
                     		
                  
 
                  		
                  Alarm Level: No alarm condition. The message is informational only.
Recovery