1067 - GWS rcvd UPU, AFTPC not in routing tbl
The EAGLE 5 ISS has received a user part unavailable (UPU) for an affected point code (AFTPC) which does not appear in the EAGLE 5 ISS routing tables. The message was discarded by gateway screening (GWS).
Example
RLGHNCXA21W 00-04-18 19:06:42 EST EAGLE 31.3.0
0132.1067 CARD 1201,A INFO GWS rcvd UPU, AFTPC not in routing tblSIO=90 OPC=004-043-000 DPC=002-000-000
H0H1=A1 AFTPC=099-099-003
SR=scrb LSN=A1234567
Legend
Alarm Level: No alarm condition. The message is informational only.
Recovery
Verify the affected point code in the message, and
verify whether the affected point code is required to be in the EAGLE 5 ISS
routing tables.
- If the affected point code is not required to be in the EAGLE 5 ISS routing tables, no further action is necessary.
- If the affected point code is required to be in the
EAGLE 5 ISS routing table, use the
ent-dstn
command to add the affected point code to the EAGLE 5 ISS routing tables.