1074 – MSU Arrived on Wrong SM Card
SCCP MSU ended up on an Service Module card, which does not contain the needed RIDB/RTDB table (ELAP, DN, or IMSI).
Format
“MSU for xxxx needs ExAP yyyy data”where xxxx = Service Name (LNP, INPQ, INPMR, VFLEX, IDPR, IAR, APORT, GPORT, TATI, ATINPQ, SMSMR, GFLEX, EIR), ExAP = ELAP/EPAP, and Yyyy = IMSI/DN
                     Example
                     
                  
                  0226.1074    CARD 1101,A1  INFO      MSU for INPMR needs EPAP DN data
                 SIO=05   OPC=1-200-2           DPC=3-054-4
                 CDPA: AI=05  SSN=006  TT=007
                       ADDR=ABCDEF0123456789ABCDE
                 CGPA: AI=14  PC=2-054-2            SSN=022
                 DATA=3a e2 38 c7 04 e7 04 35 ae e8 30 e9
                      2e cf 01 00 d0 02 83 01 f2 25 aa 0b
                      84 09 01 00 11 0a 19 49
                 LSN=ABCD123
                 Report Date:02-07-21  Time:16:20:19Alarm Level: No alarm condition. The message is only informational and MSU will be discarded.
Recovery: Make sure that the EAGLE has the SM card available for the service for which UIM is generated.