1074 – MSU Arrived on Wrong SM Card
SCCP MSU ended up on an Service Module card, which does not contain the needed RIDB/RTDB table (ELAP, DN, or IMSI).
Format
“MSU for xxxx needs ExAP yyyy data”
where xxxx = Service Name (LNP, INPQ, INPMR, VFLEX, IDPR, IAR, APORT, GPORT, TATI, ATINPQ, SMSMR, GFLEX, EIR), ExAP = ELAP/EPAP, and Yyyy = IMSI/DN
Example
0226.1074 CARD 1101,A1 INFO MSU for INPMR needs EPAP DN data
SIO=05 OPC=1-200-2 DPC=3-054-4
CDPA: AI=05 SSN=006 TT=007
ADDR=ABCDEF0123456789ABCDE
CGPA: AI=14 PC=2-054-2 SSN=022
DATA=3a e2 38 c7 04 e7 04 35 ae e8 30 e9
2e cf 01 00 d0 02 83 01 f2 25 aa 0b
84 09 01 00 11 0a 19 49
LSN=ABCD123
Report Date:02-07-21 Time:16:20:19
Alarm Level: No alarm condition. The message is only informational and MSU will be discarded.
Recovery: Make sure that the EAGLE has the SM card available for the service for which UIM is generated.