1076 - SLTC Failure: Invalid Point Code (DPC)
The signaling link test control (SLTC) has detected an invalid data pattern in the signaling link test message (SLTM) received from the adjacent point code.
 
                     		  Example 
                     		  
 
                  		
                  RLGHNCXA21W 00-04-18 19:09:22 EST  EAGLE 31.3.0
0141.1076    CARD 1201,A  INFO   SLTC failure:invalid Point Code (DPC)
ADJ PC=004-046-000   SLC=02     LEN=0f
DATA= 01 02 03 04 05 06 07 08 09 11 12 13 14 15 
                     		  Legend 
		   
                     		
                      
                     		
                  
 
                  		
                  Alarm Level: No alarm condition. The message is informational only.
Recovery
Contact the far-end and use local procedures to test the facilities for the signaling link.