1143 - GTT(FLOBR) failure: duplicate settype
This message indicates that any one of the MBR GTT Settypes (IMSI\MSISDN\VLRnb\SMRPOA\SMRPDA) is found twice in the FLOBR search path, and the fallback is set to "NO" in the last matched translation. This results in GTT failure.
Example
0018.1143 CARD 1103 INFO GTT(FLOBR) failure: duplicate settype
SIO=03 OPC=4-123-5 DPC=6-018-7
CDPA: NI=1 RI=0 GTI=04 SSNI=0 PCI=1
TT=25 NP=04 NAI=010 ADDR=123456789012345678901
PC=3-026-5 SSN=005
CGPA: NI=1 RI=0 GTI=04 SSNI=0 PCI=1
TT=100 NP=07 NAI=012 ADDR=012345678901234567890
PC=----------- SSN=004
LSN=ls2314n2 GTTSETIDX=211 215
Alarm Level: No alarm condition. The message is informational only.
Recovery
- Update the FLOBR GTT search path configuration via the
chg-gta
command so that the same MBR GTT settype is not encountered in the search path again.