TxNiddCmaUpdateFailure

Measurement ID
13033
Measurement Group
SCEF NIDD Exception
Measurement Type
Simple
Measurement Dimension
Arrayed on SCS Application Server
Description
The number of Diameter CMR Update messages for which a failure was returned by SCEF application in the given collection interval.
Collection Interval
30 min
Peg Condition
This measurement is incremented each time an ingress Diameter CMR message with a Connection-Action value CONNECTION_UPDATE fails to get processed and is responded with a result code other than 2001.
Measurement Scope
Network Element, Place Association

Recovery

  1. The response message may contain an Error-Message AVP describing the details of the problem encountered that failed the request. Possible causes may be:
    • The requested NIDD configuration (identifier by the IMSI and EPS Bearer ID) was not found in the SCEF database.