2-Site redundancy is the ability to lose an entire site,
for example due to a natural disaster or major network failure, without losing
signaling or application state data. For PCA, this means no loss of Policy
Binding or Policy Session data. To achieve site redundancy, a specific
configuration applies:
- PCA is deployed on at least one mated pair of PCA
DSRs.
- Clients and PCRFs/OCSs are able to connect to both
sites in the mated pair.
- SBR server groups are set up to use the
Active/Standby/Spare or Active/Spare redundancy model.
- System OAM (SOAM) server groups are set up to use the
Active/Standby/Spare redundancy model.
- Diameter Agent MP servers are recommended to be
engineered at 40% capacity across the mated pair.