Description of the illustration dbmin_ap_001
The network diagram has the following components:
-
One Ethernet switch
-
One Oracle Database server.
-
One Oracle Exadata Storage Server
-
Two InfiniBand switches
-
Two power distribution units (PDU A and PDU B)
There are three networks shown in the diagram. The Client Access network, Management network, and the InfiniBand network.
The Client Access network is bonded (bondeth0), and connects to Net1 and Net2 of the database server.
The Management network connects to the two PDUs and the Ethernet switch. From the Ethernet switch, it connects to Net0 and ILOM of the database server, Net0 and ILOM of the Exadata Storage Server, and to each of the InfiniBand switches.
The InfiniBand private network connects IB0 on the database server through one InfiniBand switch to IB0 on the Exadata Storage Server and IB1 on the database server through the other InfiniBand switch to IB1 on the Exadata Storage Server.
A note in the Legend state that BONETH0 can be either copper or optical links.