32112 - Device interface failure
- Alarm Group:
 - PLAT
 - Description:
 - This alarm indicates either the IP bond is not configured or is down.
 - Severity:
 - Critical
 - Instance:
 - May include AlarmLocation, AlarmId, AlarmState, AlarmSeverity, and bindVarNamesValueStr
 - HA Score:
 - Normal
 - Auto Clear Seconds:
 - 0 (zero)
 - OID:
 - eagleXgDsrTpdDeviceIfFailureNotify
 - Cause:
 - This alarm indicates either the IP bond is not configured or down.
 - Diagnostic Information:
 -  
                        				
                        
- Syscheck can be
					 manually executed in the following methods: 
					 
                              
- Login as syscheck. When logging in, syscheck runs and then the login connection is dropped. This account does not have shell access.
 - From the root
						  accoun,t the Command Line Interface can be utilized directly. 
						  
                                    
- Execute 
								
syscheck -hfor usage information. 
 - Execute 
								
 - In DSR 6.0 and
						  later, from the admusr account the Command Line Interface can be used directly
						  when called using 
						  sudo. 
						  
                                    
- Execute 
								
syscheck -hfor usage information. 
 - Execute 
								
 - Using the
						  platcfg user interface. 
						  
                                    
Note:
In versions later than TPD 6.5, root access using SSH is disabled. The admusr should be used instead. If the command is to be run as admusr, sudo must be prepended to the command and the full path to the command must be used. 
 sudo /usr/TKLC/plat/bin/netAdm query --device=<bondX>sudo /usr/TKLC/plat/bin/netAdm query --device=<slave device>cat /proc/net/bonding/bondX, where X is bond designation- ethtool <slave device>
 
 - Syscheck can be
					 manually executed in the following methods: 
					 
                              
 
Recovery: