DASCopyFailureMPCong

Measurement ID
10068
Measurement Group
DAS
Measurement Type
Simple
Measurement Dimension
Single
Description
Total number of DAS Copy Failures because the MP was congested.
Collection Interval
5 min
Peg Condition

When the MP declares congestion (declared CL1-CL3), the Message Copy function is disabled. Original messages marked for copy and held as a Pending Transactions are not copied and increment this measurement. If the Copy has been sent to the DAS peer, the Copy transaction will be allowed to complete. If the Copy transaction fails, another measurement will be incremented.

Either the MP is receiving traffic in excess of its rated capacity or the intended DAS peer is not responding in a timely fashion.

Measurement Scope
Server Group

Recovery

  1. Reduce traffic being received by the MP.
  2. Verify there are no network issues between the MP and the intended DAS peer.
  3. Ensure the intended DAS peer has sufficient capacity to process the traffic being directed to it by the MP
  4. It is recommended to contact unresolvable-reference.html#GUID-F069C6FD-5BA3-4F31-AE9E-A187D5B5F729 for assistance.