RxRbarUnkApplId

Measurement ID
10308
Measurement Group
Address Resolution Exception
Measurement Type
Simple
Measurement Dimension
Single
Description
Number of Request messages rejected due to an unknown Application ID.

Note:

The DSR Relay Agent forwarded a Request message to the address resolution application which contained an unrecognized Diameter Application ID in the header. Either a DSR Relay Agent application routing rule is misprovisioned or the Application ID is not provisioned in the RBAR routing configuration.
Collection Interval
5 min
Peg Condition
When a Request message received and the Application ID is not present in the RBAR configuration.
Measurement Scope
Server Group

Recovery

  1. View the currently provisioned Diameter Application IDs by selecting RBAR, and then Configuration, and then Applications.
  2. View the currently provisioned Application Routing Rules by selecting Diameter, and then Configuration, and then Application Routing Rules.