Go to primary content
User Data Repository Alarms, KPIs, and Measurements
Release 12.4
E82598-01
Go To Table Of Contents
Contents

Previous
Previous
Next
Next

22950 - Connection Status Inconsistency Exists

Alarm Group:
DIAM
Description:
Diameter Connection status inconsistencies exist among the DA-MPs in the DSR signaling NE.
Severity:
Critical
Instance:
<DbTblName> Name of the Diameter Connection Status Sharing Table where the Diameter Connection status inconsistency was detected.
HA Score:
Normal
Auto Clear Seconds:
0 (zero)
OID:
eagleXgDiameterConnStatusInconsistencyExistsNotify

Recovery:

  1. No action necessary.

    Note:

    DA-MP's SLDB tables are automatically audited and re-synchronized to correct inconsistencies after a log overrun has occurred. The Automatic Data Integrity Check, which was introduced in cm6.2, periodically scans almost the entire local IDB for integrity. The initial default period is 30 minutes.