13367 - UDRBE System Memory Utilization Threshold Exceeded

Alarm Type:
UDR
Description:
System memory utilization threshold exceeded. Create and update provisioning, as well as auto-enrolled operations, are suspended when critical threshold is reached. Note that update requests for existing subscribers, triggered by a PUR message on the Sh interface, will continue to be processed, regardless of alarm status. The alarm severity depends on the amount of memory being used:
  • Minor when system memory utilization exceeds 80%
  • Major when system memory utilization exceeds 83%
  • Critical when system memory utilization exceeds 85%
Severity:
Minor (Major, Critical)
Instance:
N/A
HA Score:
Normal
Auto Clear Seconds:
0
OID:
UdrbeSysMemThresh

Recovery:

  1. The alarm clears when system memory utilization falls below these thresholds:
    • <= 79% (clears Minor alarm)
    • <= 82% (clears Major alarm)
    • <= 84% (clears Critical alarm)
  2. It is recommended to call My Oracle Support.