Go to primary content
User Data Repository Alarms, KPIs, and Measurements
Release 12.4
E82598-01
Go To Table Of Contents
Contents

Previous
Previous
Next
Next

32305 - Server Platform process error

Alarm Group:
PLAT
Description:
This alarm indicates that either the minimum number of instances for a required process are not currently running or too many instances of a required process are running.
Severity:
Major
Instance:
May include AlarmLocation, AlarmId, AlarmState, AlarmSeverity, and bindVarNamesValueStr
HA Score:
Normal
Auto Clear Seconds:
0 (zero)
OID:
tpdPlatProcessError
Alarm ID:
TKSPLATMA6

Recovery:

  1. Rerun syscheck in verbose mode.
  2. If the alarm has been cleared then the problem is solved.
  3. If the alarm has not been cleared then determine the run level of the system.
  4. If system run level is not 4 then determine why the system is operating at that run level.
  5. If system run level is 4, determine why the required number of instances process(es) are not running.
  6. If the alarm persists, it is recommended to contact unresolvable-reference.htm#GUID-DD0927BD-FD0B-4CEB-86E9-98A33C12D4E0 and provide the system health check output.