Go to primary content
User Data Repository Alarms, KPIs, and Measurements
Release 12.4
E82598-01
Go To Table Of Contents
Contents

Previous
Previous
Next
Next

32535 - TPD RAID disk resync

Alarm Group:
PLAT
Description:
This alarm indicates that the RAID logical volume is currently resyncing after a failed/replaced drive, or some other change in the configuration. The output of the message will include the disk that is resyncing. This alarm should eventually clear once the resync of the disk is completed. The time it takes for this is dependent on the size of the disk and the amount of activity on the system (rebuild of 600G disks without any load takes about 75min).
Severity:
Minor
Instance:
May include AlarmLocation, AlarmId, AlarmState, AlarmSeverity, and bindVarNamesValueStr
HA Score:
Normal
Auto Clear Seconds:
0 (zero)
OID:
tpdDiskResync
Alarm ID:
TKSPLATMI36

Recovery:

  1. Run syscheck in verbose mode.
  2. If this alarm persists for several hours (depending on a load of a server, rebuilding an array can take multiple hours to finish), it is recommended to contact unresolvable-reference.htm#GUID-DD0927BD-FD0B-4CEB-86E9-98A33C12D4E0.