32301 - Server internal disk error
- Alarm Group:
- PLAT
- Description:
- This alarm indicates the server is experiencing
issues replicating data to one or more of its mirrored disk drives. This could
indicate that one of the server’s disks has either failed or is approaching
failure.
- Severity:
- Major
- Instance:
- May include AlarmLocation, AlarmId, AlarmState,
AlarmSeverity, and bindVarNamesValueStr
- HA Score:
- Normal
- Auto Clear Seconds:
- 0 (zero)
- OID:
- tpdIntDiskError
- Alarm ID:
- TKSPLATMA2
Recovery:
-
Run syscheck in verbose mode.
-
Determine the raid state of the mirrored disks,
collect data:
cat /proc/mdstat
cat /etc/raidtab
-
It is recommended to contact
unresolvable-reference.htm#GUID-DD0927BD-FD0B-4CEB-86E9-98A33C12D4E0 and
provide the system health check output and collected data.